Analysis Instrument

Industrial Online Disinfactant Water Residual Chlorine Meter Analyzer Transmitter

Shanghai Chunye Instrument Technology Co., Ltd.
  • Warranty:1 year warranty lifelong free technical support
  • Display:Digital

Base Info

  • Model NO.:T6050
  • Appliance:Food Analysis, Medical Research, Biochemistry
  • Portable:Non Portable
  • Certification:RoHS, CE, ISO9001
  • Type:Concentration Meter
  • Measure range:0-2.000 mg,L, 0-20.00 mg,L
  • Housing material:Glass+POM
  • Waterproof grade:IP68
  • Accuracy:+,-1%F.S
  • Temperature compensation:NTC10K
  • Installation thread:PG13.5
  • Pressure range:0.3MPa
  • Transport Package:1 PCS,Carton
  • Specification:Double platinum ring
  • Trademark:twinno
  • Origin:Shanghai, China
  • HS Code:9027
  • Production Capacity:2000PCS,Month
  • Package size per unit product:25.00cm * 26.00cm * 30.00cm
  • Gross weight per unit product:3.000kg
  • Lead Time:10 days (1 - 50 Pieces) 30 days (51 - 200 Pieces) 60 days (201 - 500 Pieces) To be negotiated ( > 500 Pieces)

Description

Basic Info.

Model NO. T6050 Appliance Food Analysis, Medical Research, Biochemistry Portable Non Portable Certification RoHS, CE, ISO9001 Type Concentration Meter Measure range 0-2.000 mg/L, 0-20.00 mg/L Housing material Glass+POM Waterproof grade IP68 Accuracy +/-1%F.S Temperature compensation NTC10K Installation thread PG13.5 Pressure range 0.3MPa Transport Package 1 PCS/Carton Specification Double platinum ring Trademark twinno Origin Shanghai, China HS Code 9027 Production Capacity 2000PCS/Month

Packaging & Delivery

Package size per unit product 25.00cm * 26.00cm * 30.00cm Gross weight per unit product 3.000kg Lead Time 10 days (1 - 50 Pieces)
30 days (51 - 200 Pieces)
60 days (201 - 500 Pieces)
To be negotiated ( > 500 Pieces)

Product Description


Industrial Online Disinfactant Water Residual Chlorine Meter Analyzer Transmitter

Industrial Online Disinfactant Water Residual Chlorine Meter Analyzer TransmitterIndustrial Online Disinfactant Water Residual Chlorine Meter Analyzer TransmitterIndustrial Online Disinfactant Water Residual Chlorine Meter Analyzer TransmitterIndustrial Online Disinfactant Water Residual Chlorine Meter Analyzer Transmitter



T6050
 
Online Residual Chlorine Meter

Industrial online residual chlorine meter is a water quality online monitoring and controlling instrument with microprocessor. The instrument is widely used in drinking water treatment plant, drinking water distribution network, swimming pool, water quality treatment project, sewage treatment, water disinfection (chlorine dioxide generator matching) and other industrial processes.It continuous monitoring and control residual chlorine value in water solution.

Instrument features:
Color LCD display
Intelligent menu operation
Data recording & curve Display
Various automatic calibration functions
Three sets of relay control switches 
High alarm & low alarm, hysteresis control
4-20mA&RS485 Multiple output modes
Residual chlorine,current & temperature,etc. simultaneously showed in onescreen
Password protection function to prevent misoperation by non-staff

Technical parameters:
(1)Measurement range:
Residual Chlorine:0~20.00mg/L(ppm);
Temperature:0~50.0ºC;
(2)Resolution:
Residual Chlorine:0.001mg/L;
Temperature:0.1ºC;
(3)Basic error:Temperature:±0.3ºC;
     Residual Chlorine:±1%F.S;
(4)Response time:90%less than 90s;  
(5)Two Current output:
0/4~20mA(load resistance<750Ω);
20~4mA(load resistance<750Ω);
(6)Communication output:
RS485 MODBUS RTU;
(7)Three sets of relay control contacts:
5A 250VAC,5A 30VDC;
(8)Power supply(selection):
  85~265VAC±10%,50±1Hz,power  consumption≤3W;
  9~36VDC,power consumption≤3W;
(9)Dimensions:144×144×118mm;
(10)Installation:
Panel,wall mounting and pipeline network;
Panel hole opening size:138×138mm;
(11)Protection Level:IP65;
(12)Weight:0.8kg;
(13)Working environment:
      Working temperature:-10~60ºC;
      Relative humidity: ≤90%;
      No strong magnetic field around except the geomagnetic field.



 
Model No.CS5530
Measurement methodTri-electrode method
Measure materialDouble liquid junction,annular liquid junction
Housing material/DimensionsPP, Glass, 120mm*Φ12.7mm
Waterproof gradeIP68
Measurement range0 - 5.000 mg/L, 0 - 20.00 mg/L
Accuracy±0.05mg/L;
Pressure resistance≤0.3Mpa
Temperature compensationNone or Customize NTC10K
Temperature range0-50ºC
CalibrationSample calibration
Connection methods4 core cable
Cable lengthStandard 5m cable, can be extended to 100m
Installation threadPG13.5
Application Tap water, disinfectant fluid, etc.


After Sales Service

* The warranty period is 12 months from commissioning acceptance date on. In addition, we supply 1 year warranty and lifelong free technical guiding and training.
* We guarantee the maintenance time no more than 7 working days and response time within 3 hour.
* We build instrument service profile for our clients to record the product service and maintenance conditions.
* After instruments start service, we will pay follow-ups to collect the service conditions.



FAQ

What is the mini order quantity?
MOQ: generally 1 unit/piece/set

What payment methods are supported?
Payment method: By T/T, L/C, etc.
Payment terms: Generally, We accept 100% T/T in advance, balance before shipment.

What are the available delivery methods?
Our port location: Shanghai
Delivering to: Worldwide
Delivering method: by sea, by air, by truck, by express, combined transportation

How long is the product date of delivery probably?
Delivery date differs with product type, order quantity, special requirement etc. Usually our big machine delivery date is around 15 ~ 30 days; test equipment or analyzer delivery date is around 3~7 days. Some products have stock, contact us anytime to get more information.

How long is the warranty period?
We warrants the plant supplied under agreed specification against defects in material and workmanship under normal use and service for a period of 1 years after start up of the system.

How is the technical services on the product?
You are welcome to contact us any time if you have any technical question. We will response promptly and answer to your satisfaction. If required and necessary, Engineer available to service and provide technical support for machinery overseas.



Delivery:

Industrial Online Disinfactant Water Residual Chlorine Meter Analyzer Transmitter

Industrial Online Disinfactant Water Residual Chlorine Meter Analyzer Transmitter




Our company:


Industrial Online Disinfactant Water Residual Chlorine Meter Analyzer Transmitter

     
Industrial Online Disinfactant Water Residual Chlorine Meter Analyzer Transmitter
Industrial Online Disinfactant Water Residual Chlorine Meter Analyzer Transmitter