Transformer Oil Furans Analysis HPLC System High Performance Liquid Chromatography
Chongqing Gold Mechanical & Electrical Equipment Co., Ltd.- Appliance:Transformer Oil Analysis
- Detector:FID
- Mobile Phase:Liquid
- Chromatography Type:Liquid Chromatography
- Chromatographic Column Length:10~30cm
- Chromatographic Column Diameter:10mm
Base Info
- Model NO.:GD-3100
- Product Name:High Performance Liquid Chromatography
- Application:Furfural Furan Analysis in Transformer Oil
- Flow Rate Range:0.001-10.000 Ml,Min, in 0.001 Ml Increments
- Flow Accuracy:≤±0.2% (1.00ml,Min, H2O, R.T., 8.5MPa)
- Flow Precision:Rsd≤0.06% (1.00ml,Min, H2O, R.T., 8.5MPa)
- Maximum Pressure:45 MPa
- UV3100 UV/Vis Detector:Wavelength Range: 190-700 Nm
- O3100 Colunm Oven:3 Columns
- Chromatographic Data-Process Workstation:Internal and External Standard Calculation Methods
- UV3100 UV/Vis Detector 2:Bandwidth: 8nm
- Transport Package:Plywood Case
- Trademark:GOLD
- Origin:Chongqing, China
- HS Code:9030849000
- Production Capacity:500 Pieces,Month
Description
P3100 High Pressure Constant Flow Pump
1) Flow rate range: 0.001-10.000 mL/min, in 0.001 mL increments
2) Flow accuracy: ≤±0.2% (1.00ml/min, H2O,R.T.,8.5MPa)
3) Flow precision: RSD≤0.06% (1.00ml/min, H2O,R.T.,8.5MPa)
4) Maximum pressure: 45 MPa
5) Pressure accuracy: ≤±3.0%
6) Pressure pulsation: ≤0.1 MPa
UV3100 UV/VIS Detector
- Wavelength range: 190-700 nm
- Wavelength repeatability: ≤0.1 nm
- Wavelength accuracy: ≤±1.0 nm
- Bandwidth: 8nm
- Response time: 0.0 s-5 s
- Baseline noise: ≤±0.5×10-5 AU
- Drift: ≤1.0×10-4 AU/h (empty cell, 254 nm, 60 min)
- Path length: 10 mm(analytical cell)
- Light source: Deuterium Lamp
Chromsoft Chromatographic Data-processing Workstation
- Internal and external standard calculation methods
- Automatically displays, prints, exports and starts other programs after the completion of a measurement.
- Comply with the requirements of the 21 CFR Part 11 directive of the FDA.
GD-3100 System Kits
- Containing required tubing, fittings, wreches and cables for system.
- 7725i manual injector
- TD-1-15 static mixer
- Supersil ODS2 5μm ID4.6*200mm
S3100 Autosampler
(optional)
- Inject volum range: 0-100 μL (standard)
- Precision: RSD <0.3%
- linearity: >0.999
- Sample residual: <0.01%
- Number of sample plates: Two of 60 position 2-mL vial plates
- Syringe: 500 μL
O3100 Colunm Oven
- Column capacity: Three columns, up to 10mm internal diameter, up to 250mm length with guard column
- Temperature range: Ambient+5.0 to 80ºC, settable in 0.1ºC increments
- Temperature accuracy: ≤±0.5ºC
- Temperature stability: ≤±0.1ºC
Pretreatment
(optional)
- Ultrasonic Bench Top Cleaner
- Φ13mm/Φ25mm Nylon (organic) (100/pk)
- Φ13mm/Φ25mm Cellulose (aqueous) (100/pk)
- Diaphragm Vacuum Pump
- Φ50mm Solvent Filter (Include Nylon and Cellulose, 100/pk)


Success Case
A Transformer Oil Lab from Philippines Ordered 8 Sets Equipment

A Transformer Oil Lab in Manila,Philippines who placed an order with us on July 11,2019. Total 8 equipment. which includes:
- GDYJ-502A 80KV Transformer Oil BDV Tester,
- GDGY Transformer Oil Tan Delta Tester,
- GC-7890-DL Transformer Oil Dissolved Gas Analyzer
- GD-2100 Karl Fischer Moisture Titrator(Coulometric method)
- GD-6541A Automatic Interfacial Tension Tester
- GD-752N UV Vis Spectrophotometer
- GD-3100 Gradient HPLC System
- GD-105 Automatic Acid Number Tester (ASTM D974)
We will provide a training in their lab.