Analysis Instrument

Bt 900p Portable pH/Conductivity/Dissolved Oxygen Meter

Hangzhou West Tune Trading Co., Limited
  • After-sales Service:Online Technical Support
  • Warranty:One Year
  • Display:Digital
  • Portable:Portable
  • Appliance:Biochemistry
  • Certification:ISO9001, CE

Base Info

  • Model NO.:BT900P
  • pH Range:-2.00 ~ 20.00pH
  • Resolution:0.001, 0.01, 0.1pH, Selectable
  • Accuracy:±0.002pH
  • pH Buffer Options:USA, Nist, DIN, 2 Custom Buffers
  • ORP Range:±1999mv
  • ORP Resolution:0.1, 1mv, Selectable
  • ORP Accuracy:±0.2mv
  • Measurement Modes:Relative or Absolute Mv
  • Measurement Units:Ppm, Mg,L, Mol,L, Mmol,L
  • Dissolved Oxygen Range:0.00 to 20.00mg,L
  • Do Resolution:0.01, 0.1mg,L, Selectable
  • Transport Package:Standard Export Package
  • Specification:-2.00 ~20.00 pH
  • Trademark:WEST TUNE
  • Origin:China
  • HS Code:9026809000
  • Production Capacity:200PCS

Description

Model

Bante900P

   pH

 

   Range

-2.000 to 20.000pH

   Resolution

0.001, 0.01, 0.1pH, selectable

   Accuracy

±0.002pH

   Calibration Points

1 to 5 points

   pH Buffer Options

USA, NIST, DIN, 2 custom buffers

   ORP

 

   Range

±1999.9mV

   Resolution

0.1, 1mV, selectable

   Accuracy

±0.2mV

   Calibration Points

1 point

   Measurement Modes

Relative or absolute mV

   Ion Concentration

 

   Range

0.001 to 19999 (deponding on the range of ISE)

   Resolution

0.001, 0.01, 0.1, 1

   Accuracy

±0.5% F.S. (monovalent), ±1% F.S. (divalent)

   Calibration Points

2 to 5 points

   Calibration Solutions

0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000

   Measurement Units

ppm, mg/L, mol/L, mmol/L

   Conductivity

 

   Range

0.01 to 20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm

   Resolution

0.001, 0.01, 0.1, 1

   Accuracy

±0.5% F.S.

   Calibration Points

1 to 5 points

   Calibration Solutions

10µS, 84µS, 1413µS, 12.88mS, 111.8mS

   Temperature Coefficient

Linear (0.0 to 10.0%/°C), pure water

   Reference Temperature

20/25°C

   Cell Constant  

K=0.1, 1, 10 or custom

   TDS

 

   Range

0.00 to 10.00, 100.0, 1000ppm, 10.00, 200.0ppt

   Resolution

0.01, 0.1, 1

   Accuracy

±1% F.S.

   TDS Factor

0.1 to 1.0 (default 0.5)

   Salinity

 

   Range

0.00 to 80.00ppt, 0.00 to 42.00psu

   Resolution

0.01

   Accuracy

±1% F.S.

   Resistivity

 

   Range

0.00 to 20.00MΩ

   Resolution

0.01

   Accuracy

±1% F.S.

   Dissolved Oxygen

 

   DO Range

0.00 to 20.00mg/L

   Resolution

0.01, 0.1mg/L, selectable

   Accuracy

±0.2mg/L

   % Saturation of Oxygen

0.0 to 200.0%

   Resolution

0.1, 1%, selectable

   Accuracy

±2.0%

   Calibration Points

1 or 2 points

   Pressure Correction

60.0 to 112.5kPa/450 to 850mmHg, manual

   Salinity Correction

0.0 to 50.0g/L, manual

   Temperature

 

   Range

0 to 105°C/32 to 221°F

   Resolution

0.1°C/0.1°F

   Accuracy

±0.5°C/±0.9°F

   Offset Calibration

1 point

   Calibration Range

Reading ±10°C

   General Specifications

 

   Temperature Compensation

0 to 100°C/32 to 212°F, manual or automatic

   Stability Criteria

Low or high

   Calibration Due Alarm

1 to 31 days or off

   Auto-Power Off

10, 20 or 30 minutes after last key pressed

   Memory

Stores up to 500 data sets

   Output

USB communication interface

   Connector

BNC, 6-pin nimi-DIN, 3.5mm jack socket

   Display

Custom LCD (80×60mm)

   Power

3×1.5V AA batteries or DC5V power adapter

   Battery Life

Approximately 150 hours (turn off the backlight)

   Dimensions

170(L)×85(W)×30(H)mm

   Weight

300g

P11 pH ElectrodeFor the general applicationsP11-LiCl pH ElectrodeFor the non-aqueous samplesP11-HA pH ElectrodeFor the high alkalines samplesP11-NA pH ElectrodeFor the biofuelsP12 pH ElectrodeFor the sample in the test tubeP13 pH ElectrodeFor the micro-volume samplesP15 pH ElectrodeFor the low conductivity samplesP16 pH ElectrodeFor the Tris buffersP18 pH ElectrodeFor the slurries and soilsP19 pH ElectrodeFor the semisolidsP21 pH ElectrodeFor the colloidsP22 pH ElectrodeFor the high temperature samples501 ORP ElectrodeFor the sample with strong redox potential502 ORP ElectrodeFor the sample with weak redox potentialNa-US Sodium ElectrodeRange: 0.1 to 23000ppmCL-US Chloride ElectrodeRange: 1.8 to 35500ppmF-US Fluoride ElectrodeRange: 0.02ppm to saturationCa-US Calcium ElectrodeRange: 0.02 to 4000ppmNO3-US Nitrate ElectrodeRange: 0.4 to 62000ppmBr-US Bromide ElectrodeRange: 0.4 to 79900ppmNH4-US Ammonium ElectrodeRange: 0.1 to 18000ppmCn-US Cyanide ElectrodeRange: 0.2 to 260ppmCd-US Cadmium ElectrodeRange: 0.01 to 11200ppmCu-US Copper ElectrodeRange: 0.006 to 6400ppmI-US Iodide ElectrodeRange: 0.06 to 127000ppmPb-US Lead ElectrodeRange: 0.2 to 20700ppmAg-US Silver ElectrodeRange: 0.01 to 107900ppmK-US Potassium ElectrodeRange: 0.04 to 39000ppmS-US Sulphide ElectrodeRange: 0.003 to 32100ppmNH3-US Ammonia ElectrodeRange: 0.02 to 17000ppmCON-0.1 Conductivity ElectrodeFor the pure waterCON-1 Conductivity ElectrodeFor the general waterCON-10 Conductivity ElectrodeFor the high conductivity waterDO100 Dissolved Oxygen ElectrodeFor the DO and % saturation measurementsDO Membrane CapFor the dissolved oxygen electrodeDO Electrolyte SolutionFor the dissolved oxygen electrodeTP-10K Temperature ProbeFor the temperature measurementpH Buffer Solutions480ml/bottleConductivity Standard Solutions480ml/bottleIon Standard Solutions480ml/bottleIonic Strength Adjuster480ml/bottle
About usBt 900p Portable pH/Conductivity/Dissolved Oxygen MeterBt 900p Portable pH/Conductivity/Dissolved Oxygen MeterBt 900p Portable pH/Conductivity/Dissolved Oxygen MeterBt 900p Portable pH/Conductivity/Dissolved Oxygen MeterBt 900p Portable pH/Conductivity/Dissolved Oxygen MeterBt 900p Portable pH/Conductivity/Dissolved Oxygen Meter