RS485 Digital Oxidation Reduction Potential Sensor Electrode orp
Shanghai Chunye Instrument Technology Co., Ltd.- Warranty:1 year warranty lifelong free technical support
- Display:Digital
Base Info
- Model NO.:CS2733D
- Appliance:Food Analysis, Medical Research, Biochemistry
- Portable:Non Portable
- Certification:RoHS, CE, ISO9001
- Type:Concentration Meter
- Materials:Plastic
- Power:12VDC
- Output:RS485 MODBUS RTU
- Measure material:Glass+PT
- Housing material:PP
- Waterproof grade:IP68
- Measurement range:+,-1000mV
- Accuracy:+,-3mV
- Temperature compensation:NTC10K
- Installation thread:NPT3,4 inch
- Transport Package:1 PCS,Carton
- Specification:Diameter 30mm x Height 160mm
- Trademark:Twinno
- Origin:Shanghai, China
- HS Code:9027
- Production Capacity:3000PCS,Month
- Package size per unit product:21.00cm * 10.00cm * 7.00cm
- Gross weight per unit product:1.000kg
- Lead Time:15 days (1 - 50 Pieces)
30 days (51 - 200 Pieces)
60 days (201 - 500 Pieces)
To be negotiated ( > 500 Pieces)
Description
Basic Info.
Model NO. CS2733D Appliance Food Analysis, Medical Research, Biochemistry Portable Non Portable Certification RoHS, CE, ISO9001 Type Concentration Meter Materials Plastic Power 12VDC Output RS485 MODBUS RTU Measure material Glass+PT Housing material PP Waterproof grade IP68 Measurement range +/-1000mV Accuracy +/-3mV Temperature compensation NTC10K Installation thread NPT3/4 inch Transport Package 1 PCS/Carton Specification Diameter 30mm x Height 160mm Trademark Twinno Origin Shanghai, China HS Code 9027 Production Capacity 3000PCS/MonthPackaging & Delivery
Package size per unit product 21.00cm * 10.00cm * 7.00cm Gross weight per unit product 1.000kg Lead Time 15 days (1 - 50 Pieces)30 days (51 - 200 Pieces)
60 days (201 - 500 Pieces)
To be negotiated ( > 500 Pieces)
Product Description
CS2733D Digital ORP Sensor
Designed for common water quality.
Easy to connect to PLC, DCS, industrial control computers, general purpose controllers, paperless recording instruments or touch screens and other third party devices.
Double salt bridge design, double layer seepage interface, resistant to medium reverse seepage.
The ceramic pore parameter electrode oozes out of the interface and is not easy to be blocked, which is suitable for monitoring of common water quality environmental media.
High-strength glass bulb design, the glass appearance is stronger.
The electrode adopts low noise cable, the signal output is farther and more stable
Large sensing bulbs increase the ability to sense hydrogen ions, and perform well in common water quality environment media.
Conventional online ORP electrode
- Using PTFE large ring diaphragm to ensure the durability of the electrode;
- Can be used under 6 bar pressure;
- Long service life;
- Optional for high alkali/high acid process glass;
- Optional internal NTC temperature sensor for precise temperature compensation;
- TOP 68 insertion system for reliable measurement of transmission;
- Only one electrode installation position and one connecting cable are required;
- Continuous and accurate ORP measurement system with temperature compensation.
Model No. | CS2733D |
Power/Outlet | 9~36VDC/RS485 MODBUS RTU |
Measure material | Glass+pt |
Housing material | PP |
Waterproof grade | IP68 |
Measurement range | ±2000mV |
Accuracy | ±3mV |
Pressure resistance | ≤0.6Mpa |
Temperature compensation | NTC10K |
Temperature range | 0-80ºC |
Measuring/Storage Temperature | 0-45ºC |
Calibration | Sample calibration, standard liquid calibration |
Connection methods | 4 core cable |
Cable length | Standard 10m cable, can be extended to 100m |
Installation thread | NPT3/4'' |
Application | General application, industrial water, sewage, river, lake,etc. |
After Sales Service
* The warranty period is 12 months from commissioning acceptance date on. In addition, we supply 1 year warranty and lifelong free technical guiding and training.
* We guarantee the maintenance time no more than 7 working days and response time within 3 hour.
* We build instrument service profile for our clients to record the product service and maintenance conditions.
* After instruments start service, we will pay follow-ups to collect the service conditions.
FAQ
What is the mini order quantity?
MOQ: generally 1 unit/piece/set
What payment methods are supported?
Payment method: By T/T, L/C, etc.
Payment terms: Generally, We accept 100% T/T in advance, balance before shipment.
What are the available delivery methods?
Our port location: Shanghai
Delivering to: Worldwide
Delivering method: by sea, by air, by truck, by express, combined transportation
How long is the product date of delivery probably?
Delivery date differs with product type, order quantity, special requirement etc. Usually our big machine delivery date is around 15 ~ 30 days; test equipment or analyzer delivery date is around 3~7 days. Some products have stock, contact us anytime to get more information.
How long is the warranty period?
We warrants the plant supplied under agreed specification against defects in material and workmanship under normal use and service for a period of 1 years after start up of the system.
How is the technical services on the product?
You are welcome to contact us any time if you have any technical question. We will response promptly and answer to your satisfaction. If required and necessary, Engineer available to service and provide technical support for machinery overseas.
Delivery and Packing: