Spectrum Analyzer
SpecificationSRS3030DSpectrum MeasurementRange9kHz - 3GHzResolution1HzAccuracy±(Frequency Marker Readout*Frequency ReferenceAccuracy +1%*Span +10%*RBW+0.5*[Span/(Sweep Points-1) ]+1Hz)Internal Reference(10MHz)Aging Rate < 1ppm/year; Stability Over Temperature < 0.5ppm(15C ~ 35C)Resoluti
-
Laser Diffraction Particle Size Analyzers (BT-2003)
Size Range: 0.04-1000 umSample Inflow Method: External automatic circulating and dispersing systemRepeatability: < ± 3% (CRM D50)Accuracy: < ± 3% (CRM D50)Measuring Principle: Mie scattering theoryLaser: Import optical fiber semiconductor laserOperation System: Win XP/ Win 7Conn
-
Laser Diffraction Particle Size Analyzers (BT-9300HT)
Size Range: 0.1-716 umSample Inflow Method: External peristaltic circulating and dispersing systemRepeatability: Less than 1% (CRM D50)Accuracy: Less than 1% (CRM D50)Measuring Principle: Mie scattering theoryLaser: Import optical fiber semiconductor laserOperation System: Win XP/ Win 7Connection
-
Laser Diffraction Particle Size Analyzers (BT-9300ST)
Size Range: 0.1-1000 umSample Inflow Method: Built-in automatic circulating and dispersing systemRepeatability: Less than 1% (CRM D50)Accuracy: Less than 1% (CRM D50)Measuring Principle: Mie scattering theoryLaser: Import optical fiber semiconductor laserOperation System: Win XP/ Win 7Connection Po
-
Laser Diffraction Particle Size Analyzers (Bettersize2000LD)
Size Range :0.02-2000 um(wet mode); 0.1-2000 um(dry mode)Sample Inflow Method:Circulating pump(wet mode); Turbulent flow(dry mode)Built-in automatic circulating and dispersing systemRepeatability (wet mode):Less than 1% (CRM D50)Accuracy (wet mode):Less than 1% (CRM D50)Repeatability (dry mode):Less
-
Laser Diffraction Particle Size Analyzer (Bettersize 2000E)
Size Range :0.1-2000 umSample Inflow Method:Built-in automatic circulating and dispersing systemRepeatability:Less than 1% (CRM D50)Accuracy:Less than 1% (CRM D50)Measuring Principle:Mie scattering theoryLaser:high quality optical fiber semiconductor laserOperation System:Win XP/ Win 7Connection Por
-
Intelligent Laser Particle Size Analyzer (Bettersize 2000B)
Size Range :0.01-800 umSample Inflow Method:Built-in automatic circulating and dispersing systemRepeatability:less than 1% (CRM D50)Accuracy:les than % (CRM D50)Measuring Principle:Mie scattering theoryLaser:high quality optical fiber semiconductor laserOperation System:Win XP/ Win 7Connection Port
-
Laser Particle Size Analyzer (BT-9300H)
Size Range: 0.1-340 umSample Inflow Method: External peristaltic circulating and dispersing systemRepeatability: < 1% (CRM D50)Accuracy: < 1% (CRM D50)Measuring Principle: Mie scattering theoryLaser: Import optical fiber semiconductor laserOperation System: Win XP/ Win 7Connection Port: USB or