Ncd-96s Veterinary Drug Residue Detector Wtih No Pre-Processing Tools

Zhejiang Top Cloud-Agri Technology Co., Ltd.
  • After-sales Service:Lifetime Maintenance
  • Warranty:1 Year
  • Element:Residue Detector for Veterinary Drug
  • Display:Computer Screen
  • Application:Residue Detector for Veterinary Drug
  • Transport Package:in Carton

Base Info

  • Model NO.:NCD-96S
  • Trademark:TOP
  • Origin:Zhejiang, China (Mainland)
  • HS Code:9031809090
  • Production Capacity:1000 Set,Sets Per Month

Description

Basic Info.

Model NO. NCD-96S Trademark TOP Origin Zhejiang, China (Mainland) HS Code 9031809090 Production Capacity 1000 Set/Sets Per Month

Product Description


Ncd-96s Veterinary Drug Residue Detector Wtih No Pre-Processing Tools

Scope Of Test

The instrument can quantitatively and qualitatively detect hormones and antibiotic residues in livestock products, aquatic products, and animal diseases. Aquatic product antibiotics: chloramphenicol, streptomycin, sulfonamides, furans, tetracyclines, malachite green, diethylstilbestrol, etc.; livestock product hormones: clenbuterol, ractopamine, salbutamol, dexamethasone; grain and oil products: Aflatoxin B1, M1, zearalenone, vomiting toxin; dairy products: antibiotics, melamine, etc.

Features

1. Using 800*480 resolution true color 7-inch LCD touch screen display, windows interface, Chinese man-machine dialogue operation.
2. The instrument has a power-on self-check function, and the fault is displayed on the LCD screen in real-time.
3. Filter conversion method: automatic conversion by the instrument;
4. Detection type: single and dual-wavelength and single and double hole detection methods are available for selection.
5. Layout form: Freely arrange the holes of reference, standard, and sample horizontally or vertically.
6. The energy-saving design of the automatic switch of the light source is adopted to extend the life of the light source to the maximum extent. It has the function of self-checking and alarming on the optical path and mechanical moving parts to ensure that the instrument is in good working condition.
7. Setting of project parameters: 200 test project parameters and 100,000 test data can be set, saved, modified, and inquired for future testing;
8. Detection and calibration: It has the function of detection and calibration, which can save and modify the calibration parameters and curves of 126 items. It can be called and printed when the same item is tested;
9. Use the built-in embedded micro thermal printer
10. Output: absorbance test, pesticide residue test, veterinary drug residue test (quantitative), qualitative test, a reference value, and quantitative judgment result report, and qualitative analysis of negative and positive judgment results report;
11. Support RS232 communication port; support external USB data cable to connect directly with PC; support EXCEL format data export function; support multiple comprehensive report output and summary statistics functions
12. Printing: The instrument is equipped with a built-in thermal printer or an external printer, and you can choose to automatically print or manually print the entire page test results.
13. Equipped with professional software, the PC can control any work of the instrument, realize real-time data collection, data query, and summary, supplier information management, etc.


Technical Parameters

1. Optical path system: self-calibrating 8-channel optical path system. The standard filters are 405nm, 450nm, 492nm, 630nm, and up to 10 filters are optional.
2. Light source: Quartz halogen lamp is adopted, which will automatically switch to half-pressure sleep mode when there is no operation after the machine is turned on, so as to maximize the life of the light source lamp.
3. Wavelength range: 400-1100nm
4. Wavelength accuracy: ±2.0nm
5. Half-width 8±1.0nm
6. Difference between channels: The difference in absorbance between channels of the instrument should be ≤0.02A.
7. Measuring range: 0.000-4.000Abs;
8. Resolution 0.001A
9. Accuracy: ±1% (0~2A)
10. Linearity error ±0.1% (0~2A)
11. Repeatability ±0.005A (0~2A)
12. Stability ≤0.005A/hour
13. Stray light: Use 510nm to detect 50.0g/L sodium nitrite standard solution, the absorbance should be ≥2.0A.
14. Reading speed: 5s;
15. Interface mode: RS-232/USB
16. Storage: 105 boards, more than 10,000 sets of measurement data
17. The instrument has qualitative and quantitative analysis functions and can output the original absorbance report, critical value, P/CO value, concentration data report, and qualitative analysis of negative and positive results.
18. Qualitative and quantitative calculation methods: 9 methods including single-point method, point-to-point method, linear regression method, semi-log regression, full log regression, ratio regression, ratio semi-log regression, exponential regression, and quadratic curve
19. Printing: The instrument is equipped with a built-in thermal printer or an external printer, and you can choose to automatically print or manually print the entire page test results.