Analysis Instrument

HPLC System, High Performance Liquid Chromatography Transformer Oil Analysis

Chongqing Gold Mechanical & Electrical Equipment Co., Ltd.
  • Appliance:Transformer Oil Analysis
  • Detector:FID
  • Mobile Phase:Liquid
  • Chromatography Type:Liquid Chromatography
  • Chromatographic Column Length:10~30cm
  • Chromatographic Column Diameter:10mm

Base Info

  • Product Name:High Performance Liquid Chromatography
  • Application:Furfural Furan Analysis in Transformer Oil
  • Flow Rate Range:0.001-10.000 Ml,Min, in 0.001 Ml Increments
  • Flow Accuracy:≤±0.2% (1.00ml,Min, H2O, R.T., 8.5MPa)
  • Flow Precision:Rsd≤0.06% (1.00ml,Min, H2O, R.T., 8.5MPa)
  • Maximum Pressure:45 MPa
  • UV3100 UV/Vis Detector:Wavelength Range: 190-700 Nm
  • O3100 Colunm Oven:3 Columns
  • Chromatographic Data-Process Workstation:Internal and External Standard Calculation Methods
  • UV3100 UV/Vis Detector 2:Bandwidth: 8nm
  • Transport Package:Plywood Case
  • Trademark:GOLD
  • Origin:Chongqing, China
  • HS Code:9030849000
  • Production Capacity:500 Pieces,Month

Description

1

P3100 High Pressure Constant Flow Pump

1) Flow rate range: 0.001-10.000 mL/min, in 0.001 mL increments

2) Flow accuracy: ≤±0.2% (1.00ml/min, H2O,R.T.,8.5MPa)

3) Flow precision: RSD≤0.06%  (1.00ml/min, H2O,R.T.,8.5MPa)

4) Maximum pressure: 45 MPa

5) Pressure accuracy: ≤±3.0%

6) Pressure pulsation: ≤0.1 MPa

2

UV3100 UV/VIS Detector

  • Wavelength range: 190-700 nm
  • Wavelength repeatability: ≤0.1 nm
  • Wavelength accuracy: ≤±1.0 nm
  • Bandwidth: 8nm
  • Response time: 0.0 s-5 s
  • Baseline noise: ≤±0.5×10-5 AU
  • Drift: ≤1.0×10-4 AU/h (empty cell, 254 nm, 60 min)
  • Path length: 10 mm(analytical cell)
  • Light source: Deuterium Lamp
3

Chromsoft Chromatographic Data-processing Workstation

  • Internal and external standard calculation methods
  • Automatically displays, prints, exports and starts other programs after the completion of a measurement.
  • Comply with the requirements of the 21 CFR Part 11 directive of the FDA.
4

GD-3100 System Kits

  • Containing required tubing, fittings, wreches and cables for system.
  • 7725i manual injector
  • TD-1-15 static mixer
  • Supersil ODS2 5μm ID4.6*200mm
5

S3100 Autosampler

(optional)

  • Inject volum range: 0-100 μL (standard)
  • Precision: RSD <0.3%
  • linearity: >0.999
  • Sample residual: <0.01%
  • Number of sample plates: Two of 60 position 2-mL vial plates
  • Syringe: 500 μL
6

O3100 Colunm Oven

  • Column capacity: Three columns, up to 10mm internal diameter, up to 250mm length with guard column
  • Temperature range: Ambient+5.0 to 80ºC, settable in 0.1ºC increments
  • Temperature accuracy: ≤±0.5ºC
  • Temperature stability: ≤±0.1ºC
7

Pretreatment

(optional)

  • Ultrasonic Bench Top Cleaner
  • Φ13mm/Φ25mm Nylon (organic) (100/pk)
  • Φ13mm/Φ25mm Cellulose (aqueous) (100/pk)
  • Diaphragm Vacuum Pump
  • Φ50mm Solvent Filter (Include Nylon and Cellulose, 100/pk)

HPLC System, High Performance Liquid Chromatography Transformer Oil Analysis
HPLC System, High Performance Liquid Chromatography Transformer Oil Analysis

Success Case

 A Transformer Oil Lab from Philippines Ordered 8 Sets Equipment

HPLC System, High Performance Liquid Chromatography Transformer Oil Analysis

A Transformer Oil Lab in Manila,Philippines who placed an order with us on July 11,2019. Total 8 equipment. which includes:

  • GDYJ-502A 80KV Transformer Oil BDV Tester,
  • GDGY Transformer Oil Tan Delta Tester,
  • GC-7890-DL Transformer Oil Dissolved Gas Analyzer
  • GD-2100 Karl Fischer Moisture Titrator(Coulometric method)
  • GD-6541A Automatic Interfacial Tension Tester
  • GD-752N UV Vis Spectrophotometer
  • GD-3100 Gradient HPLC System
  • GD-105 Automatic Acid Number Tester (ASTM D974)
    We will provide a training in their lab.