Analysis Instrument

Boqu Dog-2082ys High Accuracy with 4-20 Ma Output Do Controller for Dissolved Oxygen Analyzer

Shanghai Boqu Instrument Co., Ltd.
  • Display:Digital
  • Appliance:Food Analysis, Medical Research, Biochemistry
  • Certification:RoHS, FCC, CE, ISO9001
  • Name:Online Dissolved Oxygen Mater
  • Measuring Range:0~20mg,L, 0.0-200.0%
  • Power:90~260VAC

Base Info

  • Model NO.:DOG-2082YS
  • Communication:RS485 Modbus
  • Signal:4-20mA
  • Relays:3 Relays
  • Max Temperature:100c
  • Transport Package:Quality Package for International Transport
  • Specification:BOQU Instrument production over 100 000pcs,year
  • Trademark:BOQU
  • Origin:China
  • HS Code:9027809990
  • Production Capacity:100000PCS,Year

Description

Overview Detailed Photos

BOQU Contact

Boqu Dog-2082ys High Accuracy with 4-20 Ma Output Do Controller for Dissolved Oxygen Analyzer

Industrial Applicatons

Company Profile

BOQU Exhibition

Certifications

BOQU Instruments is very popular in all global markets because BOQU Water quality analysis instrument and sensors got most international certificates. As a responsible and high-tech enterprise in China, BOQU Instrument thinks there is still a long way to go, so our production is strictly according to ISO9001 from the source of raw material to the finished instrument. And there are professional staff and test instruments to check each process. now our many instruments have reached or exceeded the world-class level. BOQU instrument also got many certificates such as CE, SGS, FCC, and so on.

Boqu Dog-2082ys High Accuracy with 4-20 Ma Output Do Controller for Dissolved Oxygen AnalyzerVisit Customers

To provide better service for our customers, we will visit customers in different countries. Only in this way, then we could truly understand customer needs and help customers to choose the right water quality analyzers and sensors.

Boqu Dog-2082ys High Accuracy with 4-20 Ma Output Do Controller for Dissolved Oxygen AnalyzerFAQ

FAQ of Best Water Treatment Online Digital Dissolved Oxygen Meter

1. How can dissolved oxygen be measured using fluorescence?
A very specific energy wavelength is transmitted to a ruthenium compound immobilized in a sol-gel matrix. The ruthenium will absorb this energy, changing the outer electron's energy level. The electron will then collapse back to its original energy state, emitting the energy as a photon with a different specific wavelength. This is called "fluorescing". If the intensity of the transmitted wavelength is tightly controlled, the amount of fluorescing is both predictable and repeatable.

2. How often do the sensors need to be calibrated?
We recommend that the calibration be checked at least once a year. The sensor will drift less than one percent per year.

3. How long has this technology been in use?
Fluorescence technology has been used to measure oxygen uptake in the medical industry for decades. In the early 2000s, the technology was adapted for use in measuring dissolved oxygen in biological reactors. The key issues in making the technology viable in the water treatment industry were the durability of the sensing element and cost. Another important concern was packaging the system in a way that was easy to use and required very little maintenance. The Insite units have accomplished all of these objectives.

4. Can the sensor be calibrated in the field?
Yes, the sensor can be calibrated in the field. A simple calibration to a reference takes about a minute.