Analysis Instrument

Multi-probe Digital Sensor-pH,ORP, Conductivity/TDS/Salinity, Dissolved Oxygen,Temperature

Shanghai Chunye Instrument Technology Co., Ltd.
  • Warranty:1 year warranty lifelong free technical support
  • Display:Digital

Base Info

  • Model NO.:CS8050D
  • Appliance:Food Analysis, Medical Research, Biochemistry
  • Portable:Non Portable
  • Certification:RoHS, CE, ISO9001
  • Type:pH,ORP,TDS,EC,Salinity,DO,FCL
  • pH Range:0~14pH
  • ORP:-2000mV - 2000mV
  • Conductivity:1.0 uS,cm~ 20.0 mS,cm
  • TDS:1.0 ppm~10.00 ppt
  • Salinity:0.0~ 16.0 g,L
  • Temperature:0~60 C
  • Dissolved Oxygen:0.0-400.0%, 0.00-40.00 mg,L
  • Transport Package:1 Piece,Carton
  • Specification:Diameter 45 x Length 176 mm
  • Trademark:twinno
  • Origin:Shanghai, China
  • HS Code:9027
  • Production Capacity:1000pieces,Month

Description

Basic Info.

Model NO. CS8050D Appliance Food Analysis, Medical Research, Biochemistry Portable Non Portable Certification RoHS, CE, ISO9001 Type pH/ORP/TDS/EC/Salinity/DO/FCL pH Range 0~14pH ORP -2000mV - 2000mV Conductivity 1.0 uS/cm~ 20.0 mS/cm TDS 1.0 ppm~10.00 ppt Salinity 0.0~ 16.0 g/L Temperature 0~60 C Dissolved Oxygen 0.0-400.0%, 0.00-40.00 mg/L Transport Package 1 Piece/Carton Specification Diameter 45 x Length 176 mm Trademark twinno Origin Shanghai, China HS Code 9027 Production Capacity 1000pieces/Month

Product Description


Multi-probe Digital Sensor-pH,ORP, Conductivity/TDS/Salinity, Dissolved Oxygen,Temperature


CS8050D Multi-parameter Digital Sensor
pH,ORP, Conductivity/TDS/Salinity, Dissolved Oxygen,Temperature,RS485 Modbus RTU

 
Model No.CS8050D
Specifications 
pH0 - 14pH
Zero (pH)7.00 ± 0.25
Resolution0.01pH
Reference systemSNEX Ag/ AgCl/ KCl
Liquid junctionSNEX
ORP-2000mV - 2000mV
Resolution1mV
Accuracy±1mV
Reference system±1%
Sensitive membranePt
Liquid junctionSNEX
Conductivity1.0 μS/cm~ 20.0 mS/cm
Resolution0.1 μS/cm~ 0.01 mS/cm
Conductivity coefficientK=1.0
Temperature coefficient0.00 %~10.00 %
TDS 1.0 ppm~ 10.00 ppt
Resolution0.1 ppm~ 0.01 ppt
TDS coefficient0.40~ 1.0
Salinity0.0~ 16.0 g/L
Resolution0.1 g/L
Accuracy±0.5% FS
Salinity coefficient0.2~0.8, default(0.60)
Liquid junctionGlass,Pt
Dissolved Oxygen0.0-400.0%,0.00-40.00 mg/L
Resolution0.1%,0.01 mg/L
Accuracy±0.2% FS
Pressure+20 ~ -10 bar
Principle Polarography
Salinity compensation range0.0~50.0 ppt
Temperature compensation range0.0~50.0 °C
Pressure compensation range600~2000 mBar
Response time< 60 s (95%,25 °C)
 Stabilization time15 - 20 min
Zero drift<0.5%
Temperature0 - 60 °C
Accuracy± 0.5 °C
Unit°C
Sensor 
Housing materialPOM
DimensionsΦ72 x 205 mm
Weight1.0KGS
Electrode capNPT 1"
Cable length5m
Connectionterminals
Communication interface/protocolRS-485 Modbus RTU
Power supplyDC-12V
OutputpH,ORP,Conductivity, TDS,Salinity, Dissolved Oxygen,Temperature
Waterproof rateIP68


After Sales Service 

* The warranty period is 12 months from commissioning acceptance date on. In addition, we supply 1 year warranty and lifelong free technical guiding and training.
* We guarantee the maintenance time no more than 7 working days and response time within 3 hour.
* We build instrument service profile for our clients to record the product service and maintenance conditions.
* After instruments start service, we will pay follow-ups to collect the service conditions.



FAQ

What is the mini order quantity?
MOQ: generally 1 unit/piece/set

What payment methods are supported?
Payment method: By T/T, L/C, etc.
Payment terms: Generally, We accept 100% T/T in advance, balance before shipment.

What are the available delivery methods?
Our port location: Shanghai
Delivering to: Worldwide
Delivering method: by sea, by air, by truck, by express, combined transportation

How long is the product date of delivery probably?
Delivery date differs with product type, order quantity, special requirement etc. Usually our big machine delivery date is around 15 ~ 30 days; test equipment or analyzer delivery date is around 3~7 days. Some products have stock, contact us anytime to get more information.

How long is the warranty period?
We warrants the plant supplied under agreed specification against defects in material and workmanship under normal use and service for a period of 1 years after start up of the system.

How is the technical services on the product?
You are welcome to contact us any time if you have any technical question. We will response promptly and answer to your satisfaction. If required and necessary, Engineer available to service and provide technical support for machinery overseas.






Delivery:


Multi-probe Digital Sensor-pH,ORP, Conductivity/TDS/Salinity, Dissolved Oxygen,Temperature


Multi-probe Digital Sensor-pH,ORP, Conductivity/TDS/Salinity, Dissolved Oxygen,Temperature



Our company:

Multi-probe Digital Sensor-pH,ORP, Conductivity/TDS/Salinity, Dissolved Oxygen,Temperature
     

 Multi-probe Digital Sensor-pH,ORP, Conductivity/TDS/Salinity, Dissolved Oxygen,TemperatureMulti-probe Digital Sensor-pH,ORP, Conductivity/TDS/Salinity, Dissolved Oxygen,Temperature