Aviation Parts Burning Testing Equipment China Manufacture
Chongqing Gold Mechanical & Electrical Equipment Co., Ltd.- Warranty:12months
- Item Name:Aviation Parts Burning Testing Equipment China
- Reference Standards:Gbt2406
- Model Number:Gd-2406
- Power:AC220V, 50Hz, 50W
- Weight:70kg
Base Info
- Model NO.:GD25
- The Gas:Methane, Propane or Butane or Liquefied Petroleum
- Burning Box Size:800mm*450mm*640mm
- The Ignition Timing:0 to 99.99 Seconds Set Arbitrarily
- After Flame Time and Anti Flaming Time:0 ~ 99.99 Seconds, Accuracy ± 0.01 Seconds
- The Flame Height Measuring Device:Flame Height Ruler Is About 38.1mm
- Application:Aviation Parts Tester
- Manual:Provide
- Delivery Time:to Be Negotiated
- Oversea Training:Supply
- Transport Package:Plywood
- Trademark:GOLD
- Origin:Chongqing China(Mainland)
- HS Code:9031809090
- Production Capacity:10
Description
1.The tank is painted and equipped with viewing window;
2. The chamber dimensions: 800mm x 450mm x 640mm;
3. The automatically electronic ignition;
4. Ignition timing can be arbitrarily set around 0 ~ 99.99 seconds, continued burning time and flame time can be automatically recorded and digitally displayed;
5, The flame height can be adjusted;
6. The "push-pull" fixture;
7. The burner is located at the sliding track, easily operated, when pushed to the combustion position, automatic timing;
8. Pin valve can precisely control the gas flow and adjust standard flame height around 38.1mm;
9. According to the test samples, multiple samples holder can be chosen; customizing BWF sample size and sample holder;
10. Brand pressure gauge and pressure regulator can accurately adjust the gas pressure;
11. Bunsen burner tube inner diameter is 9.5mm; the bottom of sample must be higher than the light of 19.1mm;
12 .Thermocouple can test the maximum flame temperature about 1000 ºC; flame kerne temperature must be higher than 843 ºC;
13.The ignition time can be set freely and the buzzer can remind people when the time is over;
14. PLC microcomputer control system with touch screen can make the experimental process more automaticly and the data can be automatically recorded and stored.
Specification: