Analysis Instrument

Plastic Combustion Min. Oxygen Concentration Testing ASTM D2863 Tester

Delta Technology (Chongqing) Co., Ltd.
  • After-sales Service:Online Training, Reply Customer′s Question in 12h
  • Warranty:365 Days
  • Description:Min. Oxygen Concentration Test ASTM D2863 Tester
  • Reference Standards:ASTM D 2863, ISO 4589-2, Nes 714
  • Test Method:Automatic Paramagnetic Type
  • Function:ASTM D2863 Tester for Min. Oxygen Testing

Base Info

  • Model NO.:LOI-A
  • Oxygen Sensor:Paramagnetic Type
  • Application Field:Building Material, Cable, Rail, Plastic, etc.
  • Features:Fully Automatic ASTM D2863 Tester
  • Oxygen Range:0 - 100%
  • Gas Supplies:Oxygen, Nitrogen and Propane
  • Dimension:45cm * 40cm * 60cm
  • Weight:10kg
  • Power Supply:220V, 50Hz
  • Transport Package:Oxygen Index Test Equipment Packed in Veneer Case
  • Specification:45cm * 40cm * 60cm
  • Trademark:Delta
  • Origin:China Mainland
  • HS Code:9031809090
  • Production Capacity:1000 Sets ASTM D2863 Tester , Month

Description

Overview Product Description
  1. Product Parameters  Reference Standards
    1. Features
      1. Adopts England original Servomex Paramagnetic type oxygen sensor, which accuracy can be up to +/-0.1%;
      2. The sensor is better than traditional electrochemical sensor, because it don't need to change oxygen battery, so, it has long lift time more accurate and faster response time.
      3. Equipped with 2pcs Mass Flow Controller(MFC) to control N2 and O2 mixing ratio;
      4. Equipped with high temperature quartz glass tank;
      5. Equipped with supported and unsupported sample clamps;
      6. Equipped with portable ignition device, gas tank connector, accurate pin valve to adjust the flame;
      7. Digital setting N2 and O2 concentration;
      8. Computer+LABVIEW software to control N2 and O2 mixing ratio, read O2 concentration in mixing chamber, and store&print out test results;Plastic Combustion Min. Oxygen Concentration Testing ASTM D2863 TesterLOI-A ASTM D2863 Tester can connect with computer.
      9. Reserve a calibration port to calibrate the sensor;
      10. Stainless steel air channel design, equipped with one way fire-resistance valve, magnetic valve, fine filter, so, it is stable and safe;
      11. Patented design gas mixing chamber, which ensure the gases can mix the gases in short time, data is more accurate;
      12. Resolution: 0.1%
      13. Accuracy: +/-0.2%
      14. Response time: <300ms
      15. Oxygen stability time: <30s
      Plastic Combustion Min. Oxygen Concentration Testing ASTM D2863 TesterPlastic Combustion Min. Oxygen Concentration Testing ASTM D2863 Tester