Original Testo 310 Set Flue Gas Analyzer with Printer No. 0563 3110
Guangzhou Icecool Refrigeration Equipment Co., Ltd.- Brand:Testo
- Customized:Non-Customized
- Portable:Portable
- Certification:CE
- Gas:CO
- Type:Electrochemical Gas Analyzer
Base Info
- Model NO.:Testo 310
- Product Name:Flue Gas Analyzer
- Model Number:Testo 310
- Order Number:0563 3110
- Operating Temperature:-5 to +45 °c
- Display Type:LCD
- Display Function:Backlit 2-Line Display
- Power Supply:Battery: 1500 mAh, Mains Unit 5V,1A
- Storage Temperature:-20 to +50 °c
- Transport Package:One Piece,Box
- Specification:201 x 83 x 44 mm
- Trademark:Testo
- Origin:Germany
- HS Code:9030311000
- Production Capacity:10000PCS,Year
Description
Basic Info.
Model NO. Testo 310 Product Name Flue Gas Analyzer Model Number Testo 310 Order Number 0563 3110 Operating Temperature -5 to +45 °c Display Type LCD Display Function Backlit 2-Line Display Power Supply Battery: 1500 mAh, Mains Unit 5V/1A Storage Temperature -20 to +50 °c Transport Package One Piece/Box Specification 201 x 83 x 44 mm Trademark Testo Origin Germany HS Code 9030311000 Production Capacity 10000PCS/YearProduct Description
Original Testo 310 set flue gas analyzer With printer No.0563 3110
Feature
Robust and light instrument for daily use
30 seconds sensor zeroing
Integrated condensate trap
Integrated magnets for easy fixing to burner
testo 310 incl. battery and calibration protocol for the measurement of O2, CO, hPa and °C; IR printer (0554 3100); probe 180 mm with cone; case; mains unit incl. cable; silicon hose for pressure measurement; particle filter 5 off; 2 rolls spare thermal paper for printer.
Product Description
The testo 310 has two measurement cells for O2 and CO, and a temperature sensor integrated into the flue gas probe. The gas sensors measure the exact oxygen and carbon monoxide content as well as the flue gas and ambient temperature. From these data, all relevant measurement parameters such as CO2 value, degree of effectivity and flue gas loss are calculated. The instrument stands out thanks to its easy handling and simple menu structure. You can read off the measurement values confidently and conveniently from the well-lit display, even in bad light conditions. The fuels are stored not just as numbers, but are each described. At the top edge of the clear display, the symbols for the different measurement menus are always in view. The display and the dirt-insensitive keypad are clearly structured. Operation is very easy - even if you only have one hand free.Applications:
• Flue gas measurement
• Draught measurement
• Ambient CO measurement
• Pressure measurement
Technical Data:
Temperature - TC Type K (NiCr-Ni) | |
---|---|
Measuring range | -20 to +100 °C |
Accuracy | ±1 °C |
Resolution | 0.1 °C |
Reaction time | < 50 s |
Temperature (ambient temperature)
Temperature - TC Type J (Fe-CuNi) | |
---|---|
Measuring range | 0 to +400 °C |
Accuracy | ±1 °C (0 to +100 °C) ±1.5 % of mv (> 100 °C) |
Resolution | 0.1 °C |
Reaction time | < 50 s |
Temperature (flue gas)
Flue gas O2 | |
---|---|
Measuring range | 0 to 21 Vol.% |
Accuracy | ±0.2 Vol.% |
Resolution | 0.1 Vol.% |
Reaction time t90 | 30 s |
Flue gas Draught | |
---|---|
Measuring range | -20 to +20 hPa |
Accuracy | ±0.03 hPa (-3.00 to +3.00 hPa) ±1.5 % of mv (Remaining Range) |
Resolution | 0.01 hPa |
Flue gas degree of effectivity, Eta (calculated) | |
---|---|
Measuring range | 0 to 120 % |
Resolution | 0.1 % |
Flue gas loss (calculated) | |
---|---|
Measuring range | 0 to 99.9 % |
Resolution | 0.1 % |
Flue gas CO2 calculation (calculated from O2) | |
---|---|
Measuring range | 0 to CO2 max (Display range) |
Accuracy | ±0.2 Vol.% |
Resolution | 0.1 Vol.% |
Reaction time t90 | < 40 s |
Pressure measurement | |
---|---|
Measuring range | -40 to +40 hPa |
Accuracy | ±0.5 hPa |
Resolution | 0.1 hPa |
Flue gas CO (without H2-compensation) | |
---|---|
Measuring range | 0 to 4000 ppm |
Accuracy | ±20 ppm (0 to 400 ppm) ±5 % of mv (401 to 2000 ppm) ±10 % of mv (2001 to 4000 ppm) |
Resolution | 1 ppm |
Reaction time t90 | 60 s |
Ambient CO | |
---|---|
Measuring range | 0 to 4000 ppm |
Accuracy | ±20 ppm (0 to 400 ppm) ±5 % of mv (401 to 2000 ppm) ±10 % of mv (2001 to 4000 ppm) |
Resolution | 1 ppm |
Reaction time | 60 s |
General technical data | |
---|---|
Dimensions | 201 x 83 x 44 mm |
Operating temperature | -5 to +45 °C |
Display type | LCD |
Display function | Backlit 2-line display |
Power supply | Battery: 1500 mAh, mains unit 5V/1A |
Storage temperature | -20 to +50 °C |
Weight | (with probe) Approx. 700 g |
Product Photos:




FAQ
1. Where is your company?
we are located in Guangzhou, the capital city of Guangdong Province, near to Shenzhen, Foshan & Hong Kong, very convenient for shipping.
2. How about the MOQ?
1 unit is ok.
3. Shipping methods and lead time?
By Express: 5-7 working days to your door (DHL, UPS, TNT, FedEx...).
By Air: 7-10 working days to your airport.
By Sea: Pls advise your port of destination, the exact days will be confirmed by our forwarders, and the following lead time is for your reference.Europe and America (25 - 35 days), Asia (3-7 days), Australia ( 16-23 days).
4. What is the term of Payment?
T/T, L/C,Western Union, Paypal;
30% T/T in advance,70% before delivery.
5. What are your main products?
Compressor;
Refrigeration gas;
Refrigeration spare parts ;
Cold room panels and equipments .
6. Packaging & Shipping:
Packing: wooden pallet, wooden case or with outer carton, or as per customers' specific requirements.