Aflatoxin Tester for Testing Corn Peanuts and Grain Safety
Zhengzhou Laboao Instrument Equipment Co., Ltd.- Testing Method:Elisa Test
- Usage:Test B1,B2,G1,G2 Toxin in Food, Grain, Milk...
Base Info
- Model NO.:LAB1
- Application:Food, Grain, Fats, Milk, Pharmaceuticals, Beverage
- Min. Detection Volume:0ng
- Measuring Range:>0ng , Ml (Ppb)
- Wavelength:330 ~ 900nm
- Sensitivity:<0.1ng , Ml
- Accuracy:0.1ng , Ml
- Test Time:20test,Hour
- Transport Package:Export Package
- Specification:12 test one time
- Trademark:LABOAO
- Origin:China
- HS Code:9031809090
- Production Capacity:1000sets,Month
Description
Basic Info.
Model NO. LAB1 Application Food, Grain, Fats, Milk, Pharmaceuticals, Beverage Min. Detection Volume 0ng Measuring Range >0ng / Ml (Ppb) Wavelength 330 ~ 900nm Sensitivity <0.1ng / Ml Accuracy 0.1ng / Ml Test Time 20test/Hour Transport Package Export Package Specification 12 test one time Trademark LABOAO Origin China HS Code 9031809090 Production Capacity 1000sets/MonthProduct Description
Aflatoxin Tester For Testing Corn Peanuts And Grain Safety
Description
EAB1-2015 Microcomputer type aflatoxin, enzyme mark tester, adopts computer technology, easy to operation, has T,A,C measure and datum printing record, also dynamics part testing and Concentration of linear regression calculation, bring much convenience .
Usage
LAB1 is necessary analysis equipment for aflatoxin, ELISA analysis. Adopts the principle of using solid phase enzyme-linked immunosorbent ELISA, is consist of Aflatoxin meter and B1 kits, can quotative analysis aflatoxin B1 content in sample.
Application
LAB1 Microcomputer type aflatoxin, enzyme mark tester, also can test other mycotoxin with corresponding kits. It widely used in field of Immune pathology, microorganism antigen and antibody detection, parasitic disease diagnosis, blood disease diagnosis, plant diseases and pests and mycotoxin test in food, grain, feed, oil, milk, drink and wine.
Technical data
Measuring limit | 0ng |
Measuring range | ≥0ng / ml (ppb) |
Absorption range | -0.041~1.999(A) |
Concentration | 0.000~9999 |
Wave length | 330~900nm(450±2 nm interference filter configuration) |
Sensitivity | <0.1ng / ml |
Accuracy | ±0.1ng / ml |
Test time | 20 samples / hour |
Light source | lighting tube 3.6V/20mA |
Working environment | Temp:5~35ºC,Humidity:≤85% |
Light current stability | ≤0.3t(T)/5min |
Dark current stability | ≤0.2%t(T)/5min |
Transmittance ratio range | 0.0%t(T) ~110.0%t(T) |
(T)swift accuracy | ≤±0.004A |
Power | 40W |
Power supply | 220V±10%,50~60HZ |
Size | 410×264×110mm |
Weight | 10kg |