-
Current Transformer Test Equipment
9. Actual secondary load test10. Resistance testPARAMETERSElectrical parametersElectrical parameters - continuedStandardsMechanical parametersEnvironmental conditionsAccuracy0.2%, 0.5%Power supplyAC 220V±10% or AC 110V±10%, 50/60HzExcitation voltage output0-2500Vrms,Excitation current
-
ISO 4589-3 Elevated-Temperature Oxygen Index Testing Apparatus Tester
Product nameISO 4589-3 Elevated-Temperature Oxygen Index Testing Apparatus TesterSize435mm(W)*550mm(D)*670mm(H)Power220V, 60 Hz, 1AWeightabout 30kgManualSupplied
-
ASTM D93 SYD-261D Automatic Cleveland Open Cup Flash Point Tester
Product IntroductionThis instrument is designed and manufactured as per standards GB/T 261-2008 Determination of Flash Point - Pensky-Martens closed cup methodand ASTM D93 Standard Test Method for Flash Point by Pensky-Martens Closed Cup Tester. It is used to make determination of the closed cup fla
-
ASTM D130 Copper Strip Corrosion Test Equipment
Basic Info. Model NO. GD-5096A
-
Combustibility Analyzer Flame Testing Equipment for Building Material ISO 11925
Product nameCombustibility Analyzer Flame Testing Equipment for Building Material ISO 11925Dimension400mm(W)*700mm(D)*600(H)PowerAC 220V, 50/60Hz, 10AWeightabout 50kg
-
Nanbei Lab Plant Photosynthesis Meter
Overview Product DescriptionDetailed PhotosProduct ParametersRecommend productsCertificationsPackaging & ShippingCompany ProfileFAQQ1:Why Choose NANBEI ?(1).Professional manufacturer with more than 13 years experience(2).Exported to more than 97% Countries(3).Turnkey Solution
-
Factory Sale LCD Display Solar GPRS Weather Station
Work modeFM-tapping, optional contact, friction, phase,magnetic or electrostaticSizeΦ≤90mm,H≤20mm.Scanningrange50mm in XY direction,5mm in Z direction, alternative: 20mm in XY direction,2mm in Z directionScanningresolution0.2nm in XY direction,0.05nm in Z direction.Movementrange of sample&
-
Qlc-500 Pem Technology Technology Electrolyzer
modelParameterQLC-300QLC-500QLC-1000voltage(DC)3~5V6~8V12~15Vcurrent(DC)45A36A36AH2 production300ml/min500ml/min1000ml/minO2 production150ml/min250ml/min500ml/minNotice1, Electrolytic water must be deionized or secondary distilled water, water does not meet the standards will cause irreparable damag
-
Petroleum Products Distillation Tester (Double Tubes)
FOCUS ON OIL FILTRATION SYSTEM OVER 20 YEARSRecycling your used oil reduces pollution and protecting our environment.Conserving a valuable resource and getting paid for it. Chongqing TOP Oil Purifier Co.,Ltd.Product Descripti
-
ISO 5660 ASTM E1354 Cone Calorimeter for Building Materials
Product nameISO 5659-2 NBS Cable and Wire Smoke Density Testing EquipmentSize1,800mm(W) *900mm(D) *2,650mm(H)Weightabout 450 kgManualSuppliedExhaust50 l/sUtilitiesCompressed Air, Methane, Nitrogen, CO/CO2 Mixing Gas, Dust CollectorPower110V AC 60Hz / 230V AC 50Hz, 15A