Optical Spectrum Analyzer for Trace Metal Analysis
Optical systemOptical structureThe Paschen Runge construction full vacuum type optics systemRoom temperature35ºC±0.5ºCWavelength range170-580nmFocal length400mmGrating line3600m1/mmFirst order spectral line dispersion rare1.2nm/mmDetector Multi block high performance linear CMOS arr
-
ISO13506 ASTM F1930 Manikin Flame Engulfment Tester
Overview Detailed PhotosProduct DescriptionFAQFAQ1.What's the delivery time?About 6 months.2.What's your payment terms?30% paid by T/T in advance,70% paid by by T/T before shipping.3.What's your guarantee terms?The warranty of all products is 1 year.During this period,we are respo
-
2channels/3channels/4 Channels Ultrasonic Cross Hole Pile Tester
ItemsTechnical ParametersChannelsFour ChannelsMaster ModeARM A8 1GHzOperating SystemWinCE of Chineseoperating systemSampling ModeSynchronous SamplingDisplay Mode10.4 inchindustrialbrightLCDscreen 1024*768Operating ModeImportsofindustrialresistivetouchscreenStorage Mode(16GB)Electrical Hard DiskDepth
-
Ten Sets of Recipe-Managed Automatic Kjeldahl Nitrogen Analyzer
Basic Info. Model NO. LKN-9830
-
Multifunctional Transformer CT PT Tester Current Transformer Tester
Tests for Current Transformer:Tests for Potencial Transformer:1 Excitation curve and parameters test2 Turns ratio test3 Ratio and phase error test4 Polarity mark check5 Winding resistance measurement6 Secondary loop burden measurement7 Error line curve test for protection CT8 Transient CT parameters
-
Insulation Oil Tan Delta & Resistivity Tester Oil Dielectric Dissipation Factor
PARAMETERGDGYManual/auto.Fully-automaticACHighVoltageOutput400V-2200V±2%Every100V50VADCHighVoltageOutput0V-2200V±2%TemperatureControlRange<100ºCTemperatureMeasuringError±0.5ºCControlTemperatureError0.1ºCControlTemperatureTimeRoomTemperature90ºC<20minTem
-
Low Price 6GB+128GB Lifetime Maintenance Meter Leaf Area Tester
HUAWEI Kirin 810 (Kirin 810) eight core1. Blade length measurement range: single acquisition range is 0-110 mm (supports multiple images stitching, the longest is at least 2m)2. Blade length measurement accuracy: single acquisition measurement accuracy is ±1%, splicing accuracy can be control
-
Dws-51 Laboratory Sodium Meter
Basic Info. Model NO. DWS-51
-
GDDF-10A Multiple Frequency Induced-Voltage Test Set for transformer winding
Capacity10kVA (extendable)Input voltageAC, three phase, 380V±10% (Single phase 220V can be connected to A and C ends of power supply input. Then the capacity reduces by half.)Power frequency50HzOutput voltage0 to 350V (If with an intermediate transformer, this voltage would be higher.)Test fr