Analysis Instrument

Bante904-Cn Lab Multiparameter Conductivity/ TDS/ Do Water Quality Meter

Hangzhou West Tune Trading Co., Limited
  • After-sales Service:Online After-Sales Service
  • Warranty:1 Year
  • Display:LCD
  • Appliance:Medical Research, Biochemistry
  • Portable:Portable
  • Certification:CE

Base Info

  • Model NO.:Bante904-CN
  • Conductivity Range:0.01~20.00,200.0,2000µs,Cm,20.00,200.0ms,Cm
  • TDS Range:0~10.00, 100.0, 1000ppm, 10.00, 100.0ppt (Max. 200
  • Salinity Range:0.00~80.00ppt, 0.00~42.00PSU
  • Resistivity Range:0.00~20.00mΩ
  • Temperature Range:0~105°c, 32~221°f
  • Transport Package:Export Standard Package
  • Trademark:West Tune
  • Origin:Shanghai
  • HS Code:9027900000
  • Production Capacity:50000,Yeas

Description

Basic Info.

Model NO. Bante904-CN Conductivity Range 0.01~20.00,200.0,2000µs/Cm,20.00,200.0ms/Cm TDS Range 0~10.00, 100.0, 1000ppm, 10.00, 100.0ppt (Max. 200 Salinity Range 0.00~80.00ppt, 0.00~42.00PSU Resistivity Range 0.00~20.00mΩ Temperature Range 0~105°c, 32~221°f Transport Package Export Standard Package Trademark West Tune Origin Shanghai HS Code 9027900000 Production Capacity 50000/Yeas

Product Description

Bante904-CN Lab Multiparameter Conductivity/ TDS/ DO Water Quality Meter
Bante904-Cn Lab Multiparameter Conductivity/ TDS/ Do Water Quality MeterFEATURES:
CONDUCTIVITY/TDS/SALINITY/RESISTIVITY:
1 to 5 points push-button calibration, automatically recognizes the calibration solutions.
Selectable cell constant (0.1/1/10), normalization temperature (20°C/25°C), TDS factor, linear and pure water compensations, seawater and practical salinity measurement modes.

Bante904-Cn Lab Multiparameter Conductivity/ TDS/ Do Water Quality MeterBante904-Cn Lab Multiparameter Conductivity/ TDS/ Do Water Quality Meter
DISSOLVED OXYGEN:
1 or 2 points calibration using the air-saturated water or zero oxygen solution.
Salinity and barometric pressure compensations provide the reliable measuring results.
Selectable measurement units, including the mg/L, ppm, mmHg and kPa.
GENERAL:
Automatic Temperature Compensation provides accurate reading over the entire range.
Calibration Due Reminder prompts user to calibrate the meter regularly.
Stability indicator shows when a measurement is recognized as stable.
Auto-Hold feature senses and locks the measurement endpoint
Battery indicator shows the remaining battery capacity.
Auto-Power Off effectively conserves battery life.
Calibration report provides the details of the calibration standards and electrode slopes.
Setup menu allows setting the 15 parameters, including the number of calibration points, stability criteria, temperature unit, etc.
Reset feature automatically resumes all settings back to factory default options.
Expanded memory stores and recalls up to 500 data sets.
Stored readings can be transferred into the computer by USB communication interface.
METER INCLUDES:

Bante 904 meter: conductivity electrode, DO probe, temperature probe, conductivity standard solutions, DO electrolyte solution,power adapter.

Specifications:
ModelBante904-CN
Conductivity 
Range0.01~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm
Accuracy±0.5% F.S
Resolution0.001, 0.01, 0.1, 1
Calibration Points1 to 5 points
Calibration Solutions10µS/cm, 84µS/cm,1413µS/cm,12.88mS/cm,111.8mS/cm
Temperature Coefficient0.0~10.0%/°C
Compensation ModesLinear or Pure water
Cell ConstantK=0.1, 1, 10 or Custom
Reference Temperature20°C or 25°C
TDS 
Range0~10.00, 100.0, 1000ppm, 10.00, 100.0ppt (Max. 200ppt)
Accuracy±1% F.S
Resolution0.01, 0.1, 1
TDS Factor0.1~1.0 (Default 0.5)
Salinity 
Range0.00~80.00ppt, 0.00~42.00psu
Accuracy±1% F.S
Resolution0.01
Measurement ModesPractical salinity (psu) or Natural seawater (ppt)
Resistivity 
Range0.00~20.00MΩ
Accuracy±1% F.S
Resolution0.01, 0.1, 1
Dissolved Oxygen 
DO Range0.00~20.00mg/L
Accuracy±0.2mg/L
Resolution0.1, 0.01mg/L, selectable
% Saturation of Oxygen0.0~200.0%
Accuracy±2.0%
Resolution0.1, 1%
Calibration Points1 or 2 points
Pressure Correction60.0~112.5kPa, 450~850mmHg
Salinity Correction0~50g/L
Temperature 
Range0~105°C, 32~221°F
Accuracy±0.5°C
Resolution0.1°C, 0.1°F
Calibration Points1 point
Calibration RangeMeasured value ±10°C
General 
Temperature Compensation0~100°C, 32~212°F, Manual or Automatic
Data HoldManual or Auto-Endpoint
Stability CriteriaLow or High
Calibration Due Alarm1 to 31 days or Off
Reset FunctionYes
MemoryStores up to 500 data sets
OutputUSB communication interface
ConnectorBNC, 6-pin mini plug
DisplayLCD
PowerDC5V, using AC adapters, 220VAC/50Hz
Dimensions210(L)×188(W)×60(H)mm
Weight1.5kg

Our Company:
Bante904-Cn Lab Multiparameter Conductivity/ TDS/ Do Water Quality MeterBante904-Cn Lab Multiparameter Conductivity/ TDS/ Do Water Quality MeterBante904-Cn Lab Multiparameter Conductivity/ TDS/ Do Water Quality MeterBante904-Cn Lab Multiparameter Conductivity/ TDS/ Do Water Quality MeterBante904-Cn Lab Multiparameter Conductivity/ TDS/ Do Water Quality MeterBante904-Cn Lab Multiparameter Conductivity/ TDS/ Do Water Quality Meter


Delivery time: usually 3-15 days
Warranty: 12months
Payment methods: T/T, Western Union, Paypal, Credit Card, L/C
 
Our main lab instruments: mixer, shaker, water quality tester, autoclave, incubator, oven, water treatment(PH/DO/COND/Turbidity meter, pure water system), spectrophotometer, refractometer, peristaltic pump, heating mantle, hot plate, PCR machine, homogenizer, water bath and so on.