Analysis Instrument

ASTM D92 ASTM D93 Fully Automatic Open/Closed Flash Point Tester

Chongqing TOP Oil Purifier Co., Ltd.
  • After-sales Service:1 Year
  • Warranty:1 Year
  • Display Method:10-Inch Color Touch Screen Display in Chinese and
  • Measurement Method:Thermocouple Differential Detection Type
  • Resolution:0.1ºC
  • Printer:Low-Energy High-Speed Thermal Printer, 56 mm Paper

Base Info

  • Model NO.:TPOC-800
  • Temperature Check:Platinum Resistance (PT100Ω)
  • Ignition Method:No Gas Source Electronic Ignition
  • Self-Check Function:Automatic Diagnosis of Instrument Failure
  • Cooling Method:Forced Air Cooling
  • Power Consumption:550W
  • Power Supply:AC220V±10%
  • Dimensions:450X280X290 mm
  • Weight:About 25 Kg
  • Transport Package:Export Standard Wooden Case
  • Specification:450X280X290 mm
  • Trademark:TOP
  • Origin:Chongqing
  • HS Code:9031809090
  • Production Capacity:100 Sets,Month

Description

Basic Info.

Model NO. TPOC-800 Temperature Check Platinum Resistance (PT100Ω) Ignition Method No Gas Source Electronic Ignition Self-Check Function Automatic Diagnosis of Instrument Failure Cooling Method Forced Air Cooling Power Consumption 550W Power Supply AC220V±10% Dimensions 450X280X290 mm Weight About 25 Kg Transport Package Export Standard Wooden Case Specification 450X280X290 mm Trademark TOP Origin Chongqing HS Code 9031809090 Production Capacity 100 Sets/Month

Product Description


Fully automatic open/closed flash point tester TPOC-800
ASTM D92 ASTM D93 Fully Automatic Open/Closed Flash Point Tester

Description:
TPOC-800 full-automatic open/closed flash point tester complies with the national standard GB/T261-2008 "Determination of Flash Point Binsky-Martin Closed Cup Method", SH/T0315, ISO2719, ASTM D93 and other standards; the opening is in accordance with GB267" Petroleum products flash point and ignition point determination method (open cup method)", GB3536 "Petroleum products flash point and ignition point determination method (Cleveland open cup method)", ISO2592, ASTM D92 and other standards manufacturing, is a petroleum, chemical, electric power, environmental protection, An ideal instrument for open flash point testing in railway, scientific research and other departments.

Main feature:
1. It adopts new high-speed signal processor control, adaptive PID control algorithm, and automatically adjusts the heating curve according to the standard requirements;
2. Built-in atmospheric pressure automatic detection chip, atmospheric pressure automatic measurement, automatic correction and automatic correction of flash point value;
3. The automatic measurement of lifting, stirring, ignition, detection, alarm, cooling, and printing equipment is completed;
4. Safe, no gas source, platinum alloy electric heating wire ignition method, safe, stable, reliable, and high test accuracy;
5. Differential detection, automatic correction of system deviation, automatic stop detection and alarm when the temperature exceeds the value;
6. Powerful storage function, can store 1000 measurement results, convenient for historical query;
7. It can communicate with a notebook computer through the USB interface to realize network management;
8. Multi-language display operation, the instrument program can be upgraded when the national standard is revised;
9. The instrument is equipped with a USB interface, which can be connected to a computer or U disk, (optional) for connection operation or data export function

Technical index:
Display method:10-inch color touch screen display in Chinese and English
measurement method:Thermocouple differential detection type
Measuring range:Closing instrument: room temperature -400ºC
Opening device: room temperature -400ºC
Resolution:0.1ºC
Repeatability:Closed mouth: when the flash point value is <104ºC, the tolerance is ±1ºC, when the flash point value is ≥104ºC, the tolerance is ±2ºC
Opening: ±2ºC
Printer:Low-energy high-speed thermal printer, 56 mm paper width
temperature check:Platinum resistance (Pt100Ω)
Ignition method:No gas source electronic ignition
Self-check function:Automatic diagnosis of instrument failure
cooling method:Forced air cooling
Power consumption:<550W
Use environment:Temperature 10ºC-45ºC, humidity 30-80%
power supply:AC220V±10%
Dimensions:450X280X290 mm
weight:About 25 kg


Contact me :
ASTM D92 ASTM D93 Fully Automatic Open/Closed Flash Point Tester