Biobase Bk-Lci5100 High Performance Liquid Chromatography
Biobase Biodustry (Shandong) Co., Ltd.- Appliance:The Analysis of Environmental Samples
- Ray Type:Gamma Ray Spectrometer
- Gaspath System:Single
- Detector:TCD
- Energy Resolution:≤8%
- Spectrometer Detector:SDD
Base Info
- Model NO.:BK-LCI5100
- Stationary Phase:Solid Adsorbent
- Mobile Phase:Liquid
- Chromatography Type:Liquid Chromatography
- Chromatographic Column Type:Convetional Analytical Column
- Chromatographic Column Length:10~30cm
- Chromatographic Column Diameter:20~40mm
- Model:Bk-Lci5100
- Type:Isocratic Pump
- Flow Rate Range:0.001-10.000ml,Min, in
- Flow Accuracy:≤±0.2% (1.00ml,Min, H2O,R.T.,8.5MPa)
- Flow Precision:Rsd≤0.06% (1.00ml,Min, H2O,R.T.,8.5MPa)
- Maximum Pressure:63MPa
- Pressure Accuracy:≤±3.0%
- Pressure Pulsation:≤0.1MPa
- Wavelength Range:190-800nm
- Wavelength Repeatability:≤0.1nm
- Wavelength Accuracy:≤±1.0nm
- Band Width:6nm
- Response Time:0.0s-5s
- Baseline Noise:≤±0.25×10-5au(Empty Cell254nm, 1.
- Drift:≤0.5×10-4au,H(Empty Cell, 60min)
- Transport Package:Standard Export Package
- Specification:700*570*310mm; 700*570*350mm; 710*583*500mm; 730*
- Trademark:Biobase
- Origin:China
- Production Capacity:500,Month
Description
Model
BK-LCI5100
BK-LCG5100
BK-LCQL5100
Pump
Type
Isocratic Pump
Gradient Pump
Quarternary Low Pressure Pump
Flow Rate Range
0.001-10.000mL/min, in 0.001mL increments
Flow Accuracy
≤±0.2% (1.00ml/min, H2O,R.T.,8.5MPa)
Flow Precision
RSD≤0.06% (1.00ml/min, H2O,R.T.,8.5MPa)
Maximum Pressure
63MPa
Pressure accuracy
≤±3.0%
Pressure pulsation
≤0.1MPa
Composition rang
/
0-100%
0-100%
Composition precision
/
≤0.2%RSD
≤0.3%RSD
UV/VIS
Detector
Wavelength Range
190-800nm
Wavelength Repeatability
≤0.1nm
Wavelength Accuracy
≤±1.0nm
Band Width
6nm
Response Time
0.0s-5s
Baseline Noise
≤±0.25×10-5AU(empty cell, 254nm, 1.0s)
Drift
≤0.5×10-4AU/h(empty cell, 254nm, 60min)
Path length
10 mm(analytical cell)
Light Source
Lamp and Tungsten Lamp
Data-processing Workstation
Sequence tables for any set of samples
Internal and external standard calculation methods
Automatically displays, prints, exports and starts other programs after the completion of a measurement.
Comply with the requirements of the 21 CFR Part 11 directive of the FDA
5100 System Kits
1 Set
5100 System Manager
Integrated A/D converters
Integrated A/D converters
Integrated vacuum degasser, 4 channel
Power Supply
AC110/220V±10%, 50/60Hz
Optional Accessory
Solvent bottle,Column Oven, Auto-sampler,DAD512 Detector, Refractive Index Detector, Evaporative Light Scattering Detector, Fluorescence Detector, PC
Package Size(W*D*H)
700*570*310mm; 700*570*350mm; 710*583*500mm;
730*450*440mm; 600*440*380mm; 770*450*700mm;
Gross Weight
156kg