Automatic High Senstive ASTM D6307 Columetric Karl Fischer Titrator
Chongqing Gold Mechanical & Electrical Equipment Co., Ltd.- Type:Karl Fischer Moisture Meter
- Analysis Method:Chemical Analysis
- Display:Digital
- Application:Chemicals
- Portable:Non-portable
- Physical Analysis Type:Titration Method
Base Info
- Model NO.:GD-2100
- Chemical Analysis Type:Karl Fischer Method
- Operating Mode:Touch Screen
- Heating Mode:Standard Heating
- Off Mode:Manual
- Item Name:ASTM D6307 Columetric Karl Fischer Titrator
- Function:Determine Water Content in Oil, Liquid, etc.
- Application Field:Petroleum, Chemicals, Pharmacy, Electricity, etc.
- Measurement Range:3ppm to 100%
- Test Standards:ASTM D6307
- Advantages:High Accuracy, Good Repeatability, Low Cost
- Packing Size:56*37*39cm
- Gross Weight:13kg
- Power Supply:220V, 50Hz
- Warranty Period:1 Year
- Transport Package:Packed in Veneer Case
- Specification:320 * 240 * 180mm, 6kg
- Trademark:GOLD
- Origin:Chongqing, China
- HS Code:9031809090
- Production Capacity:10000 Sets,Month
Description
Basic Info.
Model NO. GD-2100 Chemical Analysis Type Karl Fischer Method Operating Mode Touch Screen Heating Mode Standard Heating Off Mode Manual Item Name ASTM D6307 Columetric Karl Fischer Titrator Function Determine Water Content in Oil, Liquid, etc. Application Field Petroleum, Chemicals, Pharmacy, Electricity, etc. Measurement Range 3ppm to 100% Test Standards ASTM D6307 Advantages High Accuracy, Good Repeatability, Low Cost Packing Size 56*37*39cm Gross Weight 13kg Power Supply 220V, 50Hz Warranty Period 1 Year Transport Package Packed in Veneer Case Specification 320 * 240 * 180mm, 6kg Trademark GOLD Origin Chongqing, China HS Code 9031809090 Production Capacity 10000 Sets/MonthProduct Description
GD-2100 Automatic High Senstive ASTM D6307 Columetric Karl Fischer TitratorIntroduction:
GD-2100 Automatic High Senstive ASTM D6307 Columetric Karl Fischer Titrator adopts Karl Fischer Coulometric method.
GD-2100 Automatic High Senstive ASTM D6307 Columetric Karl Fischer Titrator owns advantages of high testing accuracy, good repeatability, low testing cost etc.
GD-2100 Automatic High Senstive ASTM D6307 Columetric Karl Fischer Titrator is used to accurately test trace water content in various liquid, solid and gases.
And it is widely applied to petroleum, chemical engineering, pharmacy, electricity, scientific research, education department and so on.
Specifications:
No. | Item Name | GD-2100 Automatic High Senstive ASTM D6307 Columetric Karl Fischer Titrator |
1 | Measuring range | 3ug to 200 mg water |
2 | Water content range | 3ppm-100% |
3 | Resolution | 0.01 ug water |
4 | Accuracy | 10μg-1mg water, ± 0.2%; >1mg water, < ± 0.3% |
5 | Electrolysis speed | max 2.4 mg/min |
6 | Electrolytic current | 0 ~ 430 mA |
7 | Working environment | 5 ~ 35 ºC; Humidity: ≤85% |
8 | Dimension&Weight | 320 * 240 * 180mm, 6kg |
9 | Power supply | AC 220V ± 10% |
Features:
Intelligent DeterminationPowerful new-generation processor; dual-CPU design.
Dual power channels separate electrolytic electrode and measuring electrode; automatically removing all kinds of interference; greatly improving the accuracy of test results.
Measuring electrode data directly A / D sample converting; data true value avoids errors caused by analog circuit; results more accurate.
Easy Operation
Touch-screen operation; only pressing once then the test will be done automatically and the reported values will automatically display.
Background Compensation
Large current background compensation. Standby time can be shortened to be less than 10 minutes.
Rotating Speed Control
Software adjusting stirring speed; selection between 0 to 36.
End Point Indication
Character tips and buzzer
Perfect Calculating Function
Automatically display, calculate, print ug / ppm / percentages / mg/L / sample name / test date etc.
Automatic Date Storage
Year, month, day, hour, minute, second; automatic storage when power off.
Real Pictures:

Our Service:
Presell Service:

After-sale Service: