-
Skz1050c Two Alarm Points Carbon Monoxide Ozone Co O3 Multi Gas Measurement Unit Gas Alarm Detector Portable Gas Analyzer
Gas DetectedCarbon monoxide Ozone CO O3Detection principleElectrochemical principlesSampling MethodPump- suction, flow up 1L/min, pump suction size ten stalls adjustableData logger100,000 sets of data can be stored, storage interval available set, minimum 5S, can be browseMeasure RangeCO:( 0-1000ppm
-
Portable Skz1050c Methane Hydrogen CH4 H2 Multi Gas Leaskage Alarm Gas Detector Monitor Gas Testing Machine Gas Tester
Gas DetectedMethane hydrogen CH4 H2Detection principleCH4:(Catalytic combustion principles), H2(Electrochemical principles)Sampling MethodPump- suction, flow up 1L/min, pump suction size ten stalls adjustableData logger100,000 sets of data can be stored, storage interval available set, minimum 5S, c
-
Skz1050c Sound Light Alarm Methane Hydrogen Nitrogen CH4 H2 N2 Multi Gas Leak Test Machine Gas Testing Equipment Gas Detector Gas Analyzer
Gas DetectedMethane hydrogen nitrogen CH4 H2 N2Detection principleElectrochemical principles(H2, N2),Catalytic combustion principles(CH4)Sampling MethodPump- suction, flow up 1L/min, pump suction size ten stalls adjustableData logger100,000 sets of data can be stored, storage interval available set,
-
Skz1050c-Hydrogen Sulfide Ammonia Carbon Dioxide H2s Nh3 CO2 Gas Tester Monitor Gas Measurement Measuring Instrument Gas Alarm System Gas Meter
Gas DetectedHydrogen sulfide ammonia carbon dioxide H2S NH3 CO2Detection principleElectrochemical principles(H2S,NH3), CO2:Infrared principlesSampling MethodPump- suction, flow up 1L/min, pump suction size ten stalls adjustableData logger100,000 sets of data can be stored, storage interval available
-
Wireless Methane Hydrogen Nitrogen CH4 H2 N2 3 in 1 Multi Leakage Detector Gas Alarm System Gas Leak Test Machine
Gas DetectedMethane hydrogen nitrogen CH4 H2 N2Detection principleElectrochemical principles(H2, N2),Catalytic combustion principles(CH4)Sampling MethodPump- suction, flow up 1L/min, pump suction size ten stalls adjustableData logger100,000 sets of data can be stored, storage interval available set,
-
Accuracy Nitrogen N2 Gas Detector Alarm Gas Detector Gas Sensor Gas Detector Gas Analyzer
Gas DetectedNitrogen N2Detection principleElectrochemical principles Sampling MethodPump- suction, flow up 1L/min, pump suction size ten stalls adjustableData logger100,000 sets of data can be stored, storage interval available set, minimum 5S, can be browseMeasure Range0-100%VOLResolution0.01%VOLP
-
1 Year Warranty Carbon Dioxide CO2 Gas Detector Alarm Gas Leakage Alarm Gas Alarm System Gas Detector Sensor
Gas Detectedcarbon dioxide CO2Detection principleInfrared principles Sampling MethodPump- suction, flow up 1L/min, pump suction size ten stalls adjustableData logger100,000 sets of data can be stored, storage interval available set, minimum 5S, can be browseMeasure Range0-2000,5000,10000,50000ppm,0-
-
Multiple Frequency PT Induced Voltage Test Set
Capacity10kVA (extendable)Input voltageAC, three phase, 380V±10% (Single phase 220V can be connected to A and C ends of power supply input. Then the capacity reduces by half.)Power frequency50HzOutput voltage0 to 350V (If with an intermediate transformer, this voltage would be higher.)Test fr